Solar PV System Sizing & DC kW Array Calculator
Determine the exact DC kilowatt rating and number of solar panels required to offset 100% of annual household or facility electrical consumption.
Parameters & Inversions
Deterministic EngineCalculated Output Metrics
Analytical Proof & Invariants
Machine PrecisionRequired DC kW = Annual kWh Demand / (365 × Daily Peak Sun Hours × Derate Factor)
Step-by-Step Mathematical Derivation
Target Daily Generation E_daily = (Annual kWh × Offset% / 100) / 365. For 12,000 kWh at 100%: 32.88 kWh/day.
P_dc = E_daily / (Daily Sun Hours × Derate Factor). With 4.5 sun hours and 0.82 derate factor: 32.88 / (4.5 × 0.82) = 8.91 kW DC.
Number of Modules N = Ceil((P_dc × 1000) / Module Watts). With 410W modules: 8,910W / 410W = 21.7 ➔ 22 modules.
Standard 400W+ residential modules measure ~19.5 sq ft (1.82 m²). Required footprint = 22 × 19.5 ≈ 430 sq ft.